SARCON® PG80A

SARCON® PG80A Highly Conformable and Non-Flammable, Higher Thermal interface materials

Features

SARCON® Extremely Compressible Gap Filler Type (Putty Type) is a highly conformable, thermally conductive, non-flammable interface materials. The surface consistency is excellent for filling small air gaps and uneven mating surface, making reliable contact with various shapes and sizes of components.

CONSTRUCTION
SeriesCharacteristicsConstructions
SARCON® PG80ASilicone compound with double sticky surfaces and Thermal Conductivity of PG80A material is 13.0W/m-K by using ASTM D5470 modified*1 (8.0W/m-K by using Hot Disk)SARCON® PG80A Construction

*1) Thermal Conductivity ; Measured by using ASTM D5470 modified, refer to Fujipoly Test method FTM P-3030.

RECOMMENDED APPLICATION
SARCON® PG80A RECOMMENDED APPLICATION
THERMAL RESISTANCE
Compression
Force
0.5mmT 1.0mmT 1.5mmT 2.0mmT
100kPa /14.5psi0.5 (0.08)1.1 (0.17)1.5 (0.23)1.8 (0.28)
300kPa /43.5psi0.3 (0.05)0.4 (0.06)0.4 (0.06)0.5 (0.08)
500kPa /72.5psi0.2 (0.03)0.3 (0.05)0.3 (0.05)0.3 (0.05)

Test method: Fujipoly Test method, FTM-P3050 by TIM Tester 1300 which is ASTM D5470 equivalent
• Specimen Area; DIA.33.0mm (1.30in)

TYPICAL PROPERTIES
PropertiesUnitPG80ATest methodSpecimen
Physical
Properties
Color-BlueVisual-
Specific Gravity-3.3ASTM D792A
Electrical
Properties
Volume ResistivityOhm-m1.0x1011ASTM D257B
Breakdown VoltagekV/mm (volts/mil)12 (305)ASTM D149B
Dielectric StrengthkV/mm (volts/mil)N/AASTM D149B
Dielectric Constant -50Hz9.28 ASTM D150 A
1kHz8.58
1MHz7.76
Dissipation Factor-50Hz0.0483ASTM D150A
1kHz0.0389
1MHz0.0147
Thermal
Properties
Thermal Conductivity W/m-K13.0 by ASTM D5470ASTM D5470 -
8.0 by Hot DiskISO/CD 22007-2
Useful Temperature°C (°F)-40 to +150 (-40 to +302)--
Low molecular
Siloxane
wt% D4 to D20 Total 0.0158 or lessGas
Chromatography
-
Flame RetardantUL94V-0UL 94-

• Each Specimens are cured for measurement. • Specimen A: 2mmT • Specimen B: 120mmW × 120mmL × 1mmT
•Thermal Conductivity ; Based on Fujipoly Test Method, FTM P-1612 by Hot Disk and FTM P-3030 by ASTM D5470 modified.

COMPRESSION FORCE
Compression
Ratio
0.5mmT 1.0mmT 1.5mmT 2.0mmT
10%50 (11.3)42 (9.5)40 (9.1)29 (6.6)
20%191 (43.3)130 (29.5)95 (21.5)72 (16.3)
30%337 (76.4)215 (48.7)147 (33.3)111 (25.1)
40%474 (107.4)292 (66.2)192 (43.5)140 (31.7)
50%605 (137.1)374 (84.7)231 (52.3)166 (37.6)
Sustain 50%128 (29.0)65 (14.7)46 (10.4)41 (9.3)

Test method: Measured by ASTM D575-91 for reference
• Specimen Area; DIA.28.6mm (1.13in)
• Platen Area; DIA. 28.6mm (1.13in)
• Sustain 50%: Sustain 50% at 1 minute later
• Compression Velocity; 5.0mm/minute

DURABILITY
Test PropertyCompression
Ratio
70150
Initial100hrs250hrs500hrs1,000hrsInitial100hrs250hrs500hrs1,000hrs
Thermal Resistance30%0.830.850.840.840.820.810.780.820.850.86
Test PropertyCompression
Ratio
60/95%RH-40(30min)+125(30min)
Initial100hrs250hrs500hrs1,000hrsInitial100hrs250hrs500hrs1,000hrs
Thermal Resistance30%0.780.730.770.760.710.800.820.810.790.75

Test method: Fujipoly Test method, FTM-P3030 by ASTM D5470 modified
• Specimen Area; 15x15mm (0.59×0.59in)

reduced temperature
-40℃ = -40°F
60℃ = 140°F
70℃ = 158°F
125℃ = 257°F
150℃ = 302°F

TYPES AND CONFIGURATION
Series Product Name Thickness Sheet Size
SARCON®  PG80APG80A-00-50BL0.5mm ±0.10mm 300mm × 200mm
(Recommended Usable Size:290mm×190mm)
PG80A-00-100BL1.0mm ±0.15mm
PG80A-00-150BL1.5mm ±0.25mm
PG80A-00-200BL2.0mm ±0.35mm
Statement of Lieu of Warranty

• Properties of the products may be revised due to some changes for improving performance.
• Properties values in this document are not specification or guaranteed.
• This product is made of silicone, and silicone oil may exude from the product.
• This product is made of silicone, and low molecular siloxane may vaporize depending on operating conditions.
• The product is designed, developed, and manufactured for general industrial use only. Never use for medical, surgical, and/or relating purposes. Never use for the purpose of implantation and/or other purposes by which apart of or whole product remains in human body.
• Before using, a safety must be evaluated and verified by the purchaser.
• Contents described in the document do not guarantee the performances and qualities required for the purchaser’s specific purposes. The purchaser is responsible for pre-testing the product under the purchaser’s specific.
• Statements concerning possible or suggested uses made herein may not be relied upon, or be constructed, as a guaranty of no patent infringement.

Handling Notes

• It is recommended to use the material in up to 30% of compression ratio. Using the material beyond the recommended compression rate may result in excessive silicone oil exudation.
• It is recommended to compress the material with the equal ratio on the whole surface. Partial excessive stress may also result in excessive silicone oil exudation.

Fujipoly: Thermal Interface Materials
ISO 9001:2015