Test Properties Unit 20GAR 30GAR 45GAR Test Method
Physical Color - White visual
Thickness mm 0.20±0.05 0.30 +0.1/-0 0.45±0.05 ASTM D374
Hardness IRHD 80 87 87 ISO 7619
Tensile Strength kN/m 9.5 9.5 9.5 ASTM D412/1458
Elongation % 3 or less ASTM D412/1458
Electrical Volume Resistivity MOhm-m 2.0×109 2.0×109 2.0×109 ASTM D257
Breakdown Voltage kV/AC 10 11 12 ASTM D149
Dielectric Strngth kV/(min) 9 9 9 ASTM D150
Thermal Thermal Conductivity W/m-K 3.0 ASTM D5470
Flame Retardant - V-0 equivalent UL94

Thermal Conductivity to calculated the Thermal Resistance by TIM tester 1300 which is ASTM D5470 equivalent.

Clamping Torque versus Thermal Resistance
  Clamping Torque 20GAR 30GAR 45GAR
Thermal Resistance
(K-in2/W)
0.29 N-m 0.20 0.28 0.33
0.49 N-m 0.17 0.26 0.30
0.69 N-m 0.17 0.26 0.30

Thermal Resistance to measured by TO-3 method, refer to Fujipoly Test method “FTM-P3010” by TO-3 transistor unit.

Statement of Lieu of Warranty

• Properties of the products may be revised due to some changes for improving performance.
• Properties values in this document are not specification or guaranteed.
• This product is made of silicone, and silicone oil may exude from the product.
• This product is made of silicone, and low molecular siloxane may vaporize depending on operating conditions.
• The product is designed, developed, and manufactured for general industrial use only. Never use for medical, surgical, and/or relating purposes. Never use for the purpose of implantation and/or other purposes by which apart of or whole product remains in human body.
• Before using, a safety must be evaluated and verified by the purchaser.
• Contents described in the document do not guarantee the performances and qualities required for the purchaser’s specific purposes. The purchaser is responsible for pre-testing the product under the purchaser’s specific.
• Statements concerning possible or suggested uses made herein may not be relied upon, or be constructed, as a guaranty of no patent infringement.

Handling Notes

• It is recommended to use the material in up to 30% of compression ratio. Using the material beyond the recommended compression rate may result in excessive silicone oil exudation.
• It is recommended to compress the material with the equal ratio on the whole surface. Partial excessive stress may also result in excessive silicone oil exudation.