SARCON® GTR

SARCON® GTR General Purpose Glass cloth Reinforcement.

Features

・ SARCON® GTR is a composite of Heat Conductive Silicone Rubber and Fiberglass.
・ SARCON® GTR has excellent mechanical and physical characteristics..
・ Usable Over a Wide Temperture Range. (–60˚C ~ 182˚C / –76˚F ~ +360˚F)
・ Complies with UL 746 (Electrical Insulant Standard) 150˚C
・ Complies with UL 94 (Flame Retardancy Standard) V–0
・ Sarcon® GTR is available with a PSA (Pressure Sensitive Adhesive) mounting option.

Typical Product Properties
ItemUnitSARCON 15GTRSARCON 20GTRSARCON 30GTR
Color Greenish Gray
Thickness mm 0.15+0.02/–0.04 0.20+0.02/–0.04 0.30+0.10/–0
HardnessASTM D2240(A) 87 87 92
Tensile Strength KN/m 11
Elongation % 2 or less
Volume ResistivityMΩ . m 1 x 107 1 x 107 1 x 107
Breakdown Voltage KV/AC 4.0 6.5 8.0
Withstand Voltage KV/minute 4.0 6.0 7.0
Dielectric Constant 50Hz
103Hz
106Hz
2.5
2.5
2.5
3.2
3.2
3.2
3.5
3.5
3.5
Dielectric Dissipation Factor 50Hz
103Hz
106Hz
0.008
0.004
0.004
0.007
0.003
0.004
0.007
0.003
0.003
Thermal Impedance FTM P-3010 0.51˚C inch2/watt 0.56 ˚C inch2/watt 0.66 ˚C inch2/watt
Thermal Impedance AD Type FTM P-3010 0.78˚C inch2/watt 0.83 ˚C inch2/watt 0.93 ˚C inch2/watt
Flame Retardant UL—94 V – 0 V – 0 V – 0
Note.)1.Test Method is based on JIS K–6249.
2.Breakdown Voltage: AC 60Hz
Withstand Voltage: AC 60Hz
3.Thermal Impedance: Fujipoly Test Method FTM P-3010 which gives ASTM D5470 Equivalent value.
4.Flame Retardant: UL–94
5.Tensile Strength / ElongationTest methods according to ASTM D1458 (JIS C 2367), double silicone rubber / Glass cloth test method.
Heat Aging Test

Test Condition : 150˚C (300˚F) x 1,000hrs (42days)
SARCON® 15GTR

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 87 87 87 87
Tensile Strength (ASTM D1458) KN/m 11.0 9.1 9.1 9.1
Elongation (ASTM D1458) % 2 or less 2 or less 2 or less 2 or less
Volume ResistivityMΩ . m 5.7 x 107 7.0 x 107 1.1 x 107 9.1 x 107
Breakdown Voltage KV/AC 4.0 4.0 3.6 3.5
Dielectric Constant50Hz
103Hz
106Hz
2.5
2.5
2.5
2.2
2.2
2.2
2.3
2.3
2.3
2.3
2.2
2.3
Dielectric Dissipation Factor50Hz
103Hz
106Hz
0.008
0.004
0.004
0.006
0.003
0.003
0.002
0.002
0.003
0.002
0.002
0.003

SARCON® 20GTR

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 87 87 88 89
Tensile Strength (ASTM D1458) KN/m 10.8 9.9 9.8 7.7
Elongation (ASTM D1458) % 2 or less 2 or less 2 or less 2 or less
Volume ResistivityMΩ . m 1.1 x 107 3.9 x 107 6.8 x 107 5.8 x 107
Breakdown Voltage KV/AC 6.5 6.5 6.0 6.0
Dielectric Constant50Hz
103Hz
106Hz
3.2
3.2
3.2
2.8
2.8
2.8
2.6
2.6
2.6
2.7
2.7
2.7
Dielectric Dissipation Factor50Hz
103Hz
106Hz
0.007
0.003
0.004
0.004
0.002
0.003
0.003
0.002
0.003
0.003
0.002
0.003

SARCON® 30GTR

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 92 92 92 92
Tensile Strength (ASTM D1458) KN/m 11.0 10.4 10.0 7.0
Elongation (ASTM D1458) % 2 or less 2 or less 2 or less 2 or less
Volume ResistivityMΩ . m 1.3 x 107 3.5 x 107 4.5 x 107 8.4 x 107
Breakdown Voltage KV/AC 8.0 7.5 7.4 7.3
Dielectric Constant50Hz
103Hz
106Hz
3.5
3.5
3.5
3.3
3.3
3.3
3.4
3.4
3.4
3.3
3.3
3.3
Dielectric Dissipation Factor50Hz
103Hz
106Hz
0.007
0.003
0.003
0.003
0.002
0.003
0.002
0.001
0.003
0.002
0.001
0.003

Test Condition : 200˚C (390˚F) x 1,000hrs (42days)
SARCON® 15GTR

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 87 87 88 88
Tensile Strength (ASTM D1458) KN/m 11.0 8.5 7.4 6.6
Elongation (ASTM D1458) % 2 or less 2 or less 2 or less 2 or less
Volume ResistivityMΩ . m 5.7 x 107 7.3 x 107 1.2 x 107 1.1 x 107
Breakdown Voltage KV/AC 4.0 3.7 3.2 3.0
Dielectric Constant50Hz
103Hz
106Hz
2.5
2.5
2.5
2.3
2.3
2.3
2.1
2.1
2.1
2.1
2.1
2.1
Dielectric Dissipation Factor50Hz
103Hz
106Hz
0.008
0.004
0.004
0.003
0.002
0.003
0.003
0.002
0.002
0.003
0.002
0.002

SARCON® 20GTR

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 87 88 89 89
Tensile Strength (ASTM D1458) KN/m 10.8 10.7 7.0 6.4
Elongation (ASTM D1458) % 2 or less 2 or less 2 or less 2 or less
Volume ResistivityMΩ . m 1.1 x 107 8.3 x 107 9.8 x 107 9.8 x 107
Breakdown Voltage KV/AC 6.5 6.0 6.0 4.1
Dielectric Constant50Hz
103Hz
106Hz
3.2
3.2
3.2
2.8
2.8
2.8
2.7
2.7
2.7
2.7
2.7
2.7
Dielectric Dissipation Factor50Hz
103Hz
106Hz
0.007
0.003
0.004
0.003
0.002
0.003
0.002
0.002
0.003
0.003
0.002
0.003

SARCON® 30GTR

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 92 92 92 92
Tensile Strength (ASTM D1458) KN/m 11.0 10.5 9.6 8.5
Elongation (ASTM D1458) % 2 or less 2 or less 2 or less 2 or less
Volume ResistivityMΩ . m 1.3 x 107 6.3 x 107 1.4 x 107 8.1 x 107
Breakdown Voltage KV/AC 8.0 7.5 7.4 5.5
Dielectric Constant50Hz
103Hz
106Hz
3.5
3.5
3.5
3.4
3.4
3.4
3.2
3.2
3.2
3.2
3.1
3.1
Dielectric Dissipation Factor50Hz
103Hz
106Hz
0.007
0.003
0.003
0.002
0.001
0.003
0.002
0.001
0.003
0.002
0.002
0.003
Water resistance.

Test Condition : 60˚C (140˚F) x 500hrs(21days)

SARCON® 15GTR

PropertiesUnitBefore testAfter 250hrsAfter 500hrs
HardnessASTM D2240(A) 87 87 87
Volume ResistivityMΩ . m 5.7 x 107 1.3 x 105 9.1 x 105
Breakdown Voltage KV/AC 4.0 3.5 3.0
Dielectric Constant50Hz
103 Hz
106 Hz
2.5
2.5
2.5
2.9
2.7
2.7
2.7
2.7
2.7
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.008
0.004
0.004
0.059
0.008
0.005
0.024
0.008
0.005

SARCON® 20GTR

PropertiesUnitBefore testAfter 250hrsAfter 500hrs
HardnessASTM D2240(A) 87 87 87
Volume ResistivityMΩ . m 1.1 x 107 4.9 x 104 2.3 x 104
Breakdown Voltage KV/AC 6.5 5.0 4.0
Dielectric Constant50Hz
103 Hz
106 Hz
3.2
3.2
3.2
3.5
3.3
3.3
3.6
3.4
3.4
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.007
0.003
0.004
0.055
0.018
0.005
0.052
0.017
0.005

SARCON® 30GTR

PropertiesUnitBefore testAfter 250hrsAfter 500hrs
HardnessASTM D2240(A) 92 92 92
Volume ResistivityMΩ . m 1.3 x 107 4.0 x 105 1.3 x 105
Breakdown Voltage KV/AC 8.0 7.0 6.0
Dielectric Constant50Hz
103 Hz
106 Hz
3.5
3.5
3.5
3.9
3.7
3.6
3.9
3.7
3.6
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.007
0.003
0.003
0.042
0.018
0.005
0.041
0.020
0.005
Clamping Torque VS Thermal Impedance (°C/W ).
Clamping Torque 3kg-cm 5kg-cm 7kg-cm
Product NameThickness (mm)
15GTR0.160.580.510.50
20GTR0.210.600.560.54
30GTR0.330.680.660.64
15GTR - AD0.200.78
20GTR - AD0.250.83
30GTR - AD0.350.93

Note.) Test inethod : Fujipoly test method FTM P-3010 which gives ASTM D5470 Equivalent value.

Chemical Resistance.

(Chemical Name : HCFC AK–225 (Substitutive Freon) )

Product NameInsulative Resistivity (MΩ·m)Breakdown Voltage (KV)Thermal Impedance (˚C/W)
before soakafter 24hrsbefore soakafter 24hrsbefore soakafter 24hrs
15GTR5.7 x 1068.6 x 106440.510.50
20GTR1.1 x 1072.9 x 1076.560.560.57
30GTR1.3 x 1072.5 x 1078.090.660.69
Test Method for Thermal Resistance (Impedance).

Test method : Fujipoly test method FTM P-3010 which gives ASTM D5470 equivalent value.
1) Punched-out specimen in TO-3 package is located between a transistor and heat sink (Fig.1). and secured with screws the position (A),using a screwdriver.
2) DC 10V, 2A (20W) current is applied to the transistor.
3) After three minutes, the thermal resistance is calculated based on the following formula (B).

SARCON® GTR Testing Apparatus
Statement of Lieu of Warranty

• Properties of the products may be revised due to some changes for improving performance.
• Properties values in this document are not specification or guaranteed.
• This product is made of silicone, and silicone oil may exude from the product.
• This product is made of silicone, and low molecular siloxane may vaporize depending on operating conditions.
• The product is designed, developed, and manufactured for general industrial use only. Never use for medical, surgical, and/or relating purposes. Never use for the purpose of implantation and/or other purposes by which apart of or whole product remains in human body.
• Before using, a safety must be evaluated and verified by the purchaser.
• Contents described in the document do not guarantee the performances and qualities required for the purchaser’s specific purposes. The purchaser is responsible for pre-testing the product under the purchaser’s specific.
• Statements concerning possible or suggested uses made herein may not be relied upon, or be constructed, as a guaranty of no patent infringement.

Handling Notes

• It is recommended to use the material in up to 30% of compression ratio. Using the material beyond the recommended compression rate may result in excessive silicone oil exudation.
• It is recommended to compress the material with the equal ratio on the whole surface. Partial excessive stress may also result in excessive silicone oil exudation.

Fujipoly: Thermal Interface Materials