Typical Product Properties
ItemUnitSARCON® 30QSARCON® 45QSARCON® 85Q
Color Black
Thickness mm 0.3 +0.1 / –0 0.45 ±0.05 0.85 ±0.05
HardnessASTM D2240(A) 55
Tensile Strength KN/m 0.8 1.0 2.0
Elongation % 250
Tear Strength KN 0.5B 0.6B 1.1B
Volume Resistivity MΩ·m 1 x 106 1 x 106 1 x 106
Breakdown Voltage KV/AC 11 12 16
Withstand Voltage KV/minute 7 8 11
Dielectric Constant 50Hz
103 Hz
106 Hz
4.15
4.12
4.11
4.30
4.24
4.23
4.94
4.90
4.88
Dielectric Dissipation Factor 50Hz
103 Hz
105 Hz
0.0064
0.0035
0.0022
0.0058
0.0035
0.0020
0.0069
0.0032
0.0016
Thermal Impedance FTM P-3010 0.57 ˚C inch2/watt 0.77 ˚C inch2/watt 1.25 ˚C inch2/watt
Flame Retardant UL–94 V– 0 V– 0 V– 0
Extractable VolatilesBellcore
Test
Passed Bellcore Specification TR-NWT000930
Note.)1.Test method is based on JIS K–6249.
2.Breakdown Voltage: AC 60Hz
Withstand Voltage: AC 60Hz
3.Thermal Impedance: Fujipoly Test Method FTM P-3010 which gives ASTM D5470 Equivalent value.
4.Flame Retardant: UL–94
Heat Aging Test

Test Condition :
150˚C (300˚F) x 1,000hrs (42days)

SARCON® 30Q

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 66 65 69 73
Tensile Strength KN/m 1.2 1.4 1.5 1.6
Elongation % 168 128 118 103
Volume Resistivity MΩ·m 5.6 x 106 1.1 x 107 2.0 x 107 3.2 x 107
Breakdown Voltage KV/AC 11 11 11 10
Dielectric Constant50Hz
103 Hz
106 Hz
4.15
4.12
4.11
4.05
4.01
4.00
4.11
4.09
4.08
4.02
3.99
3.99
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0064
0.0035
0.0022
0.0063
0.0042
0.0025
0.0039
0.0027
0.0018
0.0039
0.0026
0.0022

SARCON® 45Q

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 58 61 66 69
Tensile Strength KN/m 1.2 1.6 1.8 2.0
Elongation % 207 179 140 117
Volume Resistivity MΩ·m 4.1 x 106 1.1 x 107 2.4 x 107 4.3 x 107
Breakdown Voltage KV/AC 12 11 12 12
Dielectric Constant50Hz
103 Hz
106 Hz
4.30
4.24
4.23
4.26
4.23
4.21
4.19
4.17
4.17
4.18
4.16
4.15
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0058
0.0035
0.0020
0.0053
0.0034
0.0020
0.0034
0.0024
0.0016
0.0031
0.0023
0.0017

SARCON®85Q

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 55 58 63 66
Tensile Strength KN/m 2.5 3.5 3.5 4.0
Elongation % 196 150 130 113
Volume Resistivity MΩ·m 4.6 x 106 1.5 x 107 3.2 x 107 4.1 x 107
Breakdown Voltage KV/AC 16 15 16 16
Dielectric Constant50Hz
103 Hz
106 Hz
4.94
4.90
4.88
4.87
4.84
4.82
4.88
4.86
4.84
4.86
4.83
4.82
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0069
0.0032
0.0016
0.0043
0.0027
0.0015
0.0034
0.0025
0.0017
0.0029
0.0024
0.0018

Test Condition :
200˚C (390˚F) x 1,000hrs(42days)

SARCON® 30Q

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 66 69 76 80
Tensile Strength KN/m 1.2 1.5 1.6 1.8
Elongation % 168 107 90 70
Volume Resistivity MΩ·m 5.6 x 106 1.1 x 107 3.6 x 107 7.5 x 107
Breakdown Voltage KV/AC 11 10 10 11
Dielectric Constant50Hz
103 Hz
106 Hz
4.15
4.12
4.11
4.05
4.02
4.00
3.97
3.95
3.94
3.91
3.88
3.87
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0064
0.0035
0.0022
0.0049
0.0035
0.0024
0.0034
0.0027
0.0024
0.0035
0.0031
0.0022

SARCON® 45Q

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 58 68 80 82
Tensile Strength KN/m 1.2 1.9 2.3 2.5
Elongation % 207 117 77 77
Volume Resistivity MΩ·m 4.1 x 106 2.8 x 107 4.4 x 107 6.5 x 107
Breakdown Voltage KV/AC 12 12 13 13
Dielectric Constant50Hz
103 Hz
106 Hz
4.30
4.24
4.23
4.31
4.28
4.27
4.28
4.26
4.24
4.24
4.22
4.20
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0058
0.0035
0.0020
0.0037
0.0028
0.0022
0.0029
0.0026
0.0021
0.0028
0.0028
0.0022

SARCON® 85Q

PropertiesUnitBefore testAfter 100hrsAfter 500hrsAfter 1,000hrs
HardnessASTM D2240(A) 55 62 76 78
Tensile Strength KN/m 2.5 3.8 4.9 4.8
Elongation % 196 107 117 77
Volume Resistivity MΩ·m 4.6 x 106 3.0 x 107 5.8 x 107 8.0 x 107
Breakdown Voltage KV/AC 16 17 17 18
Dielectric Constant50Hz
103 Hz
106 Hz
4.94
4.90
4.88
4.92
4.89
4.87
4.92
4.90
4.87
4.94
4.92
4.89
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0069
0.0032
0.0016
0.0034
0.0025
0.0022
0.0026
0.0025
0.0025
0.0024
0.0027
0.0025
Humidity Test.

Test Condition :
60˚C (140˚F) x 500hrs(21days) x 95%RH

SARCON® 30Q

PropertiesUnitBefore testAfter 250hrsAfter 500hrs
HardnessASTM D2240(A) 66 62 63
Tensile Strength KN/m 1.2 1.2 1.3
Elongation % 168 157 147
Volume Resistivity MΩ·m 5.6 x 106 2.9 x 107 2.8 x 107
Breakdown Voltage KV/AC 11 11 11
Dielectric Constant50Hz
103 Hz
106 Hz
4.15
4.12
4.11
4.07
4.02
3.99
4.20
4.13
4.10
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0064
0.0035
0.0022
0.0116
0.0058
0.0025
0.0132
0.0070
0.0027

SARCON® 45Q

PropertiesUnitBefore testAfter 250hrsAfter 500hrs
HardnessASTM D2240(A) 58 59 60
Tensile Strength KN/m 1.2 1.2 1.3
Elongation % 207 202 183
Volume Resistivity MΩ·m 4.1 x 106 2.5 x 107 1.9 x 107
Breakdown Voltage KV/AC 12 12 12
Dielectric Constant50Hz
103 Hz
106 Hz
4.30
4.24
4.23
4.24
4.18
4.16
4.34
4.27
4.23
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0058
0.0035
0.0020
0.0102
0.0053
0.0020
0.0136
0.0069
0.0026

SARCON® 85Q

PropertiesUnitBefore testAfter 250hrsAfter 500hrs
HardnessASTM D2240(A) 55 56 54
Tensile Strength KN/m 2.5 2.8 2.5
Elongation % 196 198 173
Volume Resistivity MΩ·m 4.6 x 106 3.5 x 107 3.5 x 107
Breakdown Voltage KV/AC 16 17 17
Dielectric Constant50Hz
103 Hz
106 Hz
4.94
4.90
4.88
4.94
4.89
4.86
4.94
4.88
4.85
Dielectric Dissipation Factor50Hz
103 Hz
106 Hz
0.0069
0.0032
0.0016
0.0093
0.0047
0.0018
0.0103
0.0053
0.0018
Clamping Torque VS Thermal Impedance (°C/W ).
Clamping Torque 3kg-cm 5kg-cm 7kg-cm
Product NameThickness (mm)
30Q0.350.610.570.52
45Q0.450.830.770.71
85Q0.851.421.251.18

Note.) Test method : Fujipoly Test Method FTM P-3010 which gives ASTM D5470 Equivalent value.

Chemical Resistance.

(Chemical Name : HCFC AK–225 (Substitutive Freon) )

Product NameInsulative Resistivity(MΩ·m)Breakdown Voltage (KV)Thermal Impedance (˚C/W)
before soakafter 24hrsbefore soakafter 24hrsbefore soakafter 24hrs
30Q5.6 x 1066.7 x 10511110.570.57
45Q4.1 x 1063.7 x 10512120.770.78
85Q4.6 x 1064.0 x 10616171.251.24
Test Method for Thermal Resistance (Impedance).

Test method : Fujipoly test method FTM P-3010 which gives ASTM D5470 equivalent value.
1) Punched-out specimen in TO-3 package is located between a transistor and heat sink (Fig.1). and secured with screws the position (A),using a screwdriver.
2) DC 10V, 2A (20W) current is applied to the transistor.
3) After three minutes, the thermal resistance is calculated based on the following formula (B).

SARCON® QR Testing Apparatus
Statement of Lieu of Warranty

• Properties of the products may be revised due to some changes for improving performance.
• Properties values in this document are not specification or guaranteed.
• This product is made of silicone, and silicone oil may exude from the product.
• This product is made of silicone, and low molecular siloxane may vaporize depending on operating conditions.
• The product is designed, developed, and manufactured for general industrial use only. Never use for medical, surgical, and/or relating purposes. Never use for the purpose of implantation and/or other purposes by which apart of or whole product remains in human body.
• Before using, a safety must be evaluated and verified by the purchaser.
• Contents described in the document do not guarantee the performances and qualities required for the purchaser’s specific purposes. The purchaser is responsible for pre-testing the product under the purchaser’s specific.
• Statements concerning possible or suggested uses made herein may not be relied upon, or be constructed, as a guaranty of no patent infringement.

Handling Notes

• It is recommended to use the material in up to 30% of compression ratio. Using the material beyond the recommended compression rate may result in excessive silicone oil exudation.
• It is recommended to compress the material with the equal ratio on the whole surface. Partial excessive stress may also result in excessive silicone oil exudation.

Fujipoly: Thermal Interface Materials
ISO 9001:2015