Frequently asked questions
No! The clips are not available from Fujipoly
No! Sarcon Thermal management material will only perform when compressed between the heat source and the heat sink.
All currently available Fujipoly Gap filler Pads are compressible to 70% of their original thickness. Normal recommended compression is 30%.
Yes, the formula is Kgf/inch2 * 2.20462 = PSI
Fujipoly’s UL file number is E58126.
The adhesive is a silicone base adhesive intended to hold the material in place until compressed. Complete details of the adhesive are available on a separate data sheet.
The volume of the slot should be equal to or slightly greater than the volume of the connector. Consider all tolerances when determining the max volume of the connector. E.g.; Connector H x W x L= Volume
UL file number?
Fujipoly’s UL file number is E58126.
A minimum aspect ratio of 1.5 to 1 is recommended. The aspect ration only applies to the Zebra itself and not the optional support material.
15mA is the current capacity for a single wire in a W Connector.
Compression set for a plain Zebra (Silver, Carbon, or Low-Temp) is 10% to 15% of the compressed amount. Compression set for a supported Zebra is 30% to 40% of the compressed amount.
The compression/deflection range for all connectors is 5% to 25%. (Series 8000 type is 8% to 20%) The recommended compression/deflection is normally 10% to 15%. Very low profile connections or very high profile connections should be verified with the factory before final selection is made.